5.3
Installation
5.3.1
Requirements for window sensor installation
Windows with attachments or decorative strips:
Square bar of window handle too long:
Square bar of window handle too short:
Product manual 2CKA001473B9425
x
Connection and installation
Prior to the installation, check
■
whether there is a free space of 19
mm to all sides from the centre of the
square hole (total width of the
window sensor is 39 mm).
If the square extension is installed
■
and the window handle cannot be set
completely onto the window sensor,
the square bar of the window handle
may have to be shortened.
For this, install the window sensor.
■
Measure the gap between the
■
window handle and the window
sensor (Pos. X) and add 2 mm.
Shorten the square bar accordingly
■
using a metal-cutting saw.
If the square bar of the window
■
handle is too short, it can be
extended with the supplied
attachment.
│24