Loading Material Filament To The Liquefiers - Stratasys FDM Vantage Series User Manual

Table of Contents

Advertisement

FDM Vantage User Guide

Loading Material Filament to the Liquefiers

If you are changing to a different material type or changing tips, follow "Changing
Material Type or Tips" on page 4-13. Loading is done automatically through that
process. If you are loading ABS blue material, see "Purging Blue Material from
Liquefier" on page 4 - 13..
After preloading material filament to the drive block, the filament must be loaded all
the way up to the liquefiers. Only one canister of each material can be loaded at a
time. Loading material to the liquefiers is done in the Idle or Paused Mode only, not
while building.
To load filament to the liquefiers:
1. From the Main Menu, select Operator Control and press ENTER.
Build Job..
>Operator Control..
Modeler Status..
Maintenance..
2. Select Load/Unload Mtl.. and press ENTER.
Unlock Door <E>
>Load/Unload Mtl..
Change Tips/Mtl..
3. Select Load Material.. and press ENTER.
>Load Material..
Unload Material..
Material Status..
Unplug Tips..
4. Scroll to the desired material to load and press ENTER. The <E> indicates the
canisters that you can select.
>M1L:ABS
M2L:PC
S1L:PC_S
S2L:ABS_S
The head warms up to the material operating temperature (Automatic - based
on SmartSpool data). This step also sets the oven temperature to the correct
value for the material being loaded.
|*Tips: Model T16
|*
| Calibrate..
| Temp Control..
| Move Head/Stage..
92.0 in3
91.6 in3
<E>
92.3 in3
<E>
41.4 in3
<E>
Material & Canisters
Support T16
(Ready)
(Loaded)
(Ready)
(Ready)