Hyundai N700E Instruction Manual page 54

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
Func-
Name
code
Overload Restriction
Overload overvoltage
b06
Restriction mode selection
Overload restriction level
b07
setting
Overload restriction
b08
constant setting
Software Lock Mode
b09 Software lock mode selection
Run-
time
Edit
Select overload or overvoltage restriction modes
0.... Overload, overvoltage restriction mode OFF
X
1.... Only overload restriction mode ON
2.... Only overvoltage restriction mode ON
3.... Overload overvoltage restriction mode ON
Sets the level for overload restriction, between 20%
and 200% of the rated current of the inverter,
X
setting range 0.2x(inverter rated current) ~
2.0x(inverter rated current)
Set the deceleration rate when inverter detects
overload, range is 0.1 to 10.0 and resolution is 0.1
Motor
current
X
Output
frequency
Prevents parameter changes, in four
options, option codes:
0.... All parameters except b09 are locked
when SFT from terminal is on
1.... All parameters except b09 and out-
X
put frequency F01 are locked when
SFT from terminal is ON
2.... All parameters except b09 are locked
3.... All parameters except b09 and output
frequency F01 setting are locked
18
Description
(b07)
(b08)
Defaults
3
180%
1.0sec
0

Hide quick links: