Hyundai N700E Instruction Manual page 43

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
2.6.3
Basic Function Mode
Func-
Name
code
F01
Output frequency setting
Acceleration time1
F02
setting
Deceleration time 1
F03
setting
F04
Rotation direction setting
Extended function of
A--
A group setting
Extended function of
b--
b group setting
Extended function of
C--
C group setting
Extended function of
H--
H group setting
Note) If you set the carrier frequency less than 2kHz, acceleration / deceleration time delays approximately
500msec.
Run-
time
Edit
Standard default target frequency that
determines constant motor that deter-mines
constant motor speed. units of 0.01Hz setting range
O
is 0.00 to 400.0Hz.
frequency setting from UP/DOWN key of
digital operator.
0.1 ~ 3000sec
Minimum
O
setting range
0.1~3000sec
Minimum
O
setting range
Two options: select codes:
X
0... Forward run
1... Reverse run
Basic setting functions
-
setting range : A01∼A65.
Fine tuning functions
-
Setting range :b01∼b27.
Terminal setting functions
-
Setting range :C01∼C21.
Sensorless vector setting functions
-
Setting range :H01∼H11.
7
Description
0.1 ~ 999.9 --- by 0.1sec
1000 ~ 3000 --- by 1sec
0.1 ~ 999.9 --- by 0.1sec
1000 ~ 3000 --- by 1sec
Defaults
volume
setting
value
30.0sec
30.0sec
0
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents