PID P(proportional)
A47
gain setting
PID I (integral)
A48
gain setting
PID D(derivative)
A49
gain setting
A50 PID scale factor setting
Feed-back method
A51
setting
Proportional gain has a range of 0.1 to 100 in the units
O
of 0.1
Integral time constant has a range of
O
0.0 to 100.0 seconds in units of 0.1
Derivative gain has a range of 0.0 to 100 .0 seconds
O
in units of 0.1
PID scale factor (multiplier),
X
range of 0.1 to 1000 in units of 0.1.
Selects source of PID, option codes:
X
0.... "OI" terminal(current in put)
1.... "O" terminal(voltage in put)
12
10.0%
10.0sec
0.0sec
100.0
0