Hyundai N700E Instruction Manual page 45

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
N700E INSTRUCTION MANUAL
External frequency end
A08
rate setting (O, OI)
Func-
Name
code
External frequency start
A09
pattern setting
External frequency
A10
sampling setting
Multi-speed Frequency Setting
A11
Multi-speed frequency
~
setting
A25
Jogging frequency
A26
setting
Jogging stop operation
A27
selection
V/F Characteristics
Torque boost mode
A28
selection
The ending point(offset) for the active
X
analog input range(0∼10V, 4mA∼20mA)
setting range is 0 to 100% in units of 0.1%
Run-
time
Edit
Two options: select codes:
Frquency
(A06)
(A05)
X
4V
4mA
0--- start at start frequency
1--- start at 0Hz
Range n = 1 to 8, where n = number of samples for
X
average
·Defines the first speed of a multi-speed profile,
range is 0 to 400Hz in units of 0.01Hz.
O
·Setting range is 1-speed(A11) to 15-speed(A25).
·Speed0 : volume setting value
Defines limited speed for jog, range is 0.5 to 10.00Hz
in units of 0.01Hz.
O
The jogging frequency is provided safety during
manual operation.
Define how end of jog stops the motor:
three options:
0.... Free-run stop
X
1.... Deceleration stop(depending on
deceleration time)
2.... DC braking stop(necessary to set DC braking)
Two options: 0.... Manual torque boost
X
1.... Automatic torque boost
9
Description
(A09=0)
(A09=1)
(A07)
(A08)
Analog input
20mA
100.0%
Defaults
0
10V
4
speed1:5Hz
speed2:10Hz
speed3:15Hz
speed4:20Hz
speed5:30Hz
speed6:40Hz
speed7:50Hz
speed8:60Hz
etc. 0Hz
0.50Hz
0
0