Hyundai N700E Instruction Manual page 44

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

2.6.4
Expanded Function Mode of A Group
Func-
Name
code
Basic parameter settings
Frequency command
A01
(Multi-speed command
method)
A02 Run command
A03 Base frequency setting
Maximum frequency
A04
setting
Analog Input Settings
External frequency setting
A05
start (O, OI)
External frequency setting
A06
end (O, OI)
External frequency start
A07
rate setting (O, OI)
Run-
time
Edit
Four options: select codes:
0.... Keypad potentiometer
X
1.... Control terminal input
2.... Standard operator
3.... Remote operator(communication)
Set the method of run commanding:
0.... Standard operator
X
1.... Control terminal input
2.... Remote operator(communication)
Settable from 0 to maximum frequency in units of
0.01Hz
V
100%
X
Settable from the base frequency [A03]
X
up to 400Hz in units of 0.01 Hz.
Start frequency provided when analog input is
0V (4mA) can be set in units of 0.01Hz setting
range is 0 to 400 Hz
Frquency
(A06)
X
(A05)
4mA
End frequency provided when analog input is 10V
X
(20mA) can be set in units of 0.01Hz. Setting range is
0 to 400Hz
The starting point(offset) for the active
X
analog input range(0∼10V, 4mA∼20mA)
setting range is 0 to 100% in units of 0.1%
8
Description
(A04)
Base
Maximum
frequency
frequency
(A03)
(A07)
(A08)
0V
Analog input
Defaults
1
1
60.00Hz
60.00Hz
0.00Hz
10V
20mA
0.00Hz
0.0%