Fvxs09/12/15/18Nvju - Daikin 4MXL-T Series Service Manual

Multi-split type air conditioners
Table of Contents

Advertisement

SiUS121827E
1.5

FVXS09/12/15/18NVJU

Control PCB
1)
(PCB2)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
E1
V2
V1
H2
H3
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
Note
The symbols in the parenthesis are the names on the appropriate wiring diagram.
Part 3 Printed Circuit Board Connector Wiring Diagram
S1
Connector for DC fan motor
S21
Connector for centralized control (HA)
S26
Connector for service PCB (PCB3)
S32
Indoor heat exchanger thermistor
S41
Connector for lower air outlet motor
S42
Connector for swing motor
S46
Connector for display/signal receiver PCB (PCB4)
S48
Connector for sensor PCB (PCB1)
H1, H2, H3
Connector for terminal strip
E1
Terminal for ground wire
JA
Address setting jumper
∗ Refer to page 258 for details.
JB
Fan speed setting when compressor stops for thermostat OFF
∗ Refer to page 261 for details.
JC
Power failure recovery function
∗ Refer to page 261 for details.
FU1 (F1U),
Fuse (3.15 A, 250 V)
FU2 (F2U)
LED A
LED for service monitor (green)
V1, V2
Varistor
FU2
FU1
H1
S1
LED A S21 S41 S42
Indoor Unit
JB
JA
JC
S32
S48
S46
S26
2P383711-1
45