Outdoor Unit

6. Outdoor Unit

Main PCB (PCB1)
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
17)
18)
19)
20)
21)
22)
23)
54
S, S10
Connector for terminal block (indoor - outdoor transmission)
S15
Connector for COOL/HEAT lock
∗ Refer to page 275 for details.
S20 (white)
Connector for electronic expansion valve coil A port
S21 (red)
Connector for electronic expansion valve coil B port
S22 (blue)
Connector for electronic expansion valve coil C port
S23 (yellow)
Connector for electronic expansion valve coil D port
S24 (white)
Connector for electronic expansion valve coil E port (5MXS-T only)
S25 (red)
Connector for electronic expansion valve coil for bypass circuit
S40
Connector for overload protector
S70
Connector for DC fan motor
S80
Connector for four way valve coil
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
S92
Connector for gas pipe thermistor
S93
Connector for liquid pipe thermistor
S201, S202
Connector for service monitor PCB (PCB2)
HL1, HN1
Connector for terminal strip (power supply)
E1, E2, E3
Connector for ground wire
U, V, W
Connector for compressor
FU1
Fuse (3.15 A, 250 V)
FU2
Fuse (5 A, 250 V)
FU3
Fuse (56 A, 250 V)
FU10
Fuse (10 A, 250 V)
V3, V4, V401
Varistor
Part 3 Printed Circuit Board Connector Wiring Diagram