SiUS121827E
2. Motions (in cooling)
In FAN operation, the fan speed is reduced by 60 rpm when no one is in the area.
When there is no signal from the motion sensor in 20 minutes, the microcomputer judges that
3. Airflow direction in 2-area INTELLIGENT EYE operation
Detection method: The opposite area of detected area is set as the target direction.
1. Human detection signal ON in both areas A and B: Shift the airflow direction to area B (left side)
2. Human detection signal ON in area A: Shift the airflow direction to area B (left side)
3. Human detection signal ON in area B: Shift the airflow direction to area A (right side)
4. Human detection signal OFF in both areas A and B: No change
∗ When the human detection signal is OFF for 20 minutes in both areas A and B, the unit starts
energy saving operation.
Note(s)
For dry operation, the temperature cannot be set with a remote controller, but the target
temperature is shifted internally.
Part 4 Functions and Control
within
20 min.
ON
Human detection
signal
OFF
Target temperature
ON
Remote controller
Sensor button
OFF
ON
Operation
OFF
Fan speed (#)
OFF
nobody is in the room and operates the unit at a temperature shifted from the target
temperature. (Cooling/Dry: 1 ~ 2°C (1.8 ~ 3.6°F) higher, Heating: 2°C (3.6°F) lower, Auto:
according to the operation mode at that time)
Left
20 min.
↑
Reset
1 ~ 2°C (1.8 ~ 3.6 °F)
Set speed
60 rpm
Indoor unit
Human
Area A
Area B
RA Indoor Unit Functions
within
20 min.
↑
Reset
Set speed
Wall
Top view
Right
(R3853)
within
20 min.
↑
Reset
(R23920)