Daikin 4MXL-T Series Service Manual page 68

Multi-split type air conditioners
Table of Contents

Advertisement

RA Indoor Unit Functions
FVXS series
Upward airflow
Upward airflow
3-D Airflow
FTXR, CTXG, CTXS, FTXS Series
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room.
When the horizontal swing and vertical swing are both set to automatic operation, the airflow
becomes 3-D airflow. The horizontal and vertical swing motions are alternated and the airflow
direction changes in the order shown in the following diagram.
(1): The vertical blades (louvers) move from the right to the left.
(2): The horizontal blades (flaps) move downward.
(3): The vertical blades (louvers) move from the left to the right.
(4): The horizontal blades (flaps) move upward.
COMFORT
FTXR, CTXG, CTXS, FTXS Series
AIRFLOW
The flaps are controlled not to blow the air directly at the people in the room.
Operation
The airflow will be in the upward direction while in cooling operation and in the downward direction
while in heating operation, which will provide a comfortable wind that will not come in direct contact
with people.
62
Flap (up and down)
Cooling/Dry
limit OFF
limit ON
Heating
R4003397
R4003396
R4003394
R4003394
(1)
(2)
(3)
(4)
(R19554)
Part 4 Functions and Control
SiUS121827E