Daikin 4MXL-T Series Service Manual page 44

Multi-split type air conditioners
Table of Contents

Advertisement

Indoor Unit
Display/Signal
1)
Receiver PCB
2)
(A2P)
3)
4)
5)
6)
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
INTELLIGENT
1)
EYE Sensor PCB
(A3P)
38
S51
Connector for control PCB (A1P)
S52
Connector for room temperature thermistor
S1W
Indoor unit ON/OFF switch
H1P
LED for operation (multi-color)
H2P
LED for INTELLIGENT EYE (green)
JA
Address setting jumper
∗ Refer to page 258 for details.
H1P
S36
Connector for control PCB (A1P)
H2P
S51
S1W
3P357402-2
S36
3E860004-1
Part 3 Printed Circuit Board Connector Wiring Diagram
SiUS121827E
S52
JA