Number
Severity
162
Warning
163
Warning
166
Warning
167
Warning
170
Info.
171
Info.
Description/Recommended actions
All enclosure EMPs are disabled.
Recommended actions:
Download the debug logs from your storage system and contact technical support. A service technician
can use the debug logs to determine the problem.
The host WWNs (node and port) previously presented by this controller module are unknown. In a dual-
controller system this event has two possible causes:
One or both controller modules have been replaced or moved while the system was powered off.
One or both controller modules have had their flash configuration cleared (this is where the previously
used WWNs are stored).
The controller module recovers from this situation by generating a WWN based on its own serial number.
Recommended actions:
If the controller module was replaced or someone reprogrammed its FRU ID data, verify the WWN
information for this controller module on all hosts that access it.
The host WWNs (node and port) previously presented by the partner controller module, which is currently
offline, are unknown.
This event has two possible causes:
The online controller module reporting the event was replaced or moved while the system was powered
off.
The online controller module had its flash configuration (where previously used WWNs are stored) cleared.
The online controller module recovers from this situation by generating a WWN based on its own serial number
for the other controller module.
Recommended actions:
If the controller module was replaced or someone reprogrammed its FRU ID data, verify the WWN
information for the other controller module on all hosts that access it.
The RAID metadata level of the two controllers does not match, which indicates that the controllers have
different firmware levels.
Usually, the controller at the higher firmware level can read metadata written by a controller at a lower
firmware level. The reverse is typically not true. Therefore, if the controller at the higher firmware level failed,
the surviving controller at the lower firmware level cannot read the metadata in disks that have failed over.
Recommended actions:
If this occurs after a firmware update, it indicates that the metadata format changed, which is rare. Update
the controller with the lower firmware level to match the firmware level in the other controller.
A diagnostic test at controller bootup detected an abnormal operation, which might require a power cycle to
correct.
Recommended actions:
Download the debug logs from your storage system and contact technical support. A service technician
can use the debug logs to determine the problem.
The last rescan detected that the indicated enclosure was added to the system.
Recommended actions:
No action is required.
The last rescan detected that the indicated enclosure was removed from the system.
Events and event messages