Number
Severity
266
Info.
267
Error
268
Info.
269
Error
Info.
270
Warning
271
Info.
106
Events and event messages
Description/Recommended actions
Recommended actions:
Replace the disk with one of the same type (SSD, enterprise SAS, or midline SAS) and the same or greater
capacity.
Configure the disk as a spare.
A volume-copy operation for the indicated master volume has been aborted by a user.
Recommended actions:
No action is required.
A volume-copy operation completed with a failure.
This event has two variants:
1
If the source volume is a master volume, you can remount it. If the source volume is a snapshot, do not
remount it until the copy is complete (as indicated by event 268).
2
Possible causes are the pool running out of available space and crossing the high threshold, volumes
being unavailable, or general I/O errors.
Recommended actions:
For variant 1: No action is required.
For variant 2: Look for other events logged at approximately the same time that indicate a pool space or
volume failure. Follow the recommended actions for those events.
A volume-copy operation for the indicated volume has completed.
Recommended actions:
No action is required.
A partner firmware upgrade attempt aborted because of either general system health issue(s) or unwritable
cache data that would be lost during a firmware update.
Recommended actions:
Resolve before retrying a firmware update. For health issues, issue the CLI show system command to
determine the specific health issue(s). For unwritten cache data, use the CLI show unwritable-
cache command
A partner firmware update operation has started. This operation is used to copy firmware from one controller
to the other to bring both controllers up to the same version of firmware.
Recommended actions:
No action is required.
Either there was a problem reading or writing the persistent IP data from the FRU ID SEEPROM, or invalid
data were read from the FRU ID SEEPROM.
Recommended actions:
Check the IP settings (including iSCSI host-port IP settings for an iSCSI system), and update them if they
are incorrect.
The storage system could not get a valid serial number from the controller's FRU ID SEEPROM, either
because it couldn't read the FRU ID data, or because the data in it are not valid or have not been programmed.
Therefore, the MAC address is derived by using the controller's serial number from flash. This event is only
logged one time during bootup.
Recommended actions: