Dell EMC ME4 Series Owner's Manual page 103

Hide thumbs Also See for ME4 Series:
Table of Contents

Advertisement

Number
Severity
233
Warning
235
Error
Info.
236
Error
Info.
237
Error
Info.
238
Warning
239
Warning
240
Warning
Description/Recommended actions
The indicated disk type is invalid and is not allowed in the current configuration.
All disks of the disallowed type have been removed from the configuration.
Recommended actions:
Replace the disallowed disks with ones that are supported.
An enclosure management processor (EMP) detected a serious error.
Recommended actions:
Replace the indicated controller module or expansion module.
An enclosure management processor (EMP) reported an event.
Recommended actions:
No action is required.
A special shutdown operation has started. These special shutdown types indicate an incompatible feature.
Recommended actions:
Replace the indicated controller module with one that supports the indicated feature.
A special shutdown operation has started. These special shutdown types are used as part of the firmware-
update process.
Recommended actions:
No action is required.
A firmware update attempt was aborted because of either general system health issue(s), or unwritable cache
data that would be lost during a firmware update.
Recommended actions:
Resolve before retrying a firmware update. For health issues, issue the CLI show system command to
determine the specific health issue(s). For unwritten cache data, use the CLI show unwritable-
cache command
A firmware update has started and is in progress. This event provides details of the steps in a firmware-update
operation that may be of interest if you have problems updating firmware.
Recommended actions:
No action is required.
An attempt to install a licensed feature failed due to an invalid license.
Recommended actions:
Check the license for what is allowed for the platform, make corrections as appropriate, and reinstall.
A timeout occurred while flushing the CompactFlash.
Recommended actions:
Restart the Storage Controller that logged this event.
If this event is logged again, shut down the Storage Controller and replace the CompactFlash.
.
A failure occurred while flushing the CompactFlash.
Events and event messages
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me4012Me412Me4084Me484Me4024Me424

Table of Contents