Events and event messages
Description/Recommended actions
Recommended actions:
Be sure to complete the trust procedure as documented in the CLI help for the trust command.
The controller enabled or disabled the indicated parameters for one or more disks.
Recommended actions:
No action is required.
The current controller has unkilled the partner controller. The other controller will restart.
Recommended actions:
No action is required.
The partner controller is changing state (shutting down or restarting).
Recommended actions:
No action is required.
The current controller that logged this event forced the partner controller to fail over.
Recommended actions:
Download the debug logs from your storage system and contact technical support. A service technician
can use the debug logs to determine the problem.
Host-port or disk-channel parameters have been changed.
Recommended actions:
No action is required.
The mirrored configuration retrieved by this controller from the partner controller has a bad cyclic redundancy
check (CRC). The local flash configuration will be used instead.
Recommended actions:
Restore the default configuration by using the restore defaults command, as described in the CLI
Reference Guide.
The mirrored configuration retrieved by this controller from the partner controller is corrupt. The local flash
configuration will be used instead.
Recommended actions:
Restore the default configuration by using the restore defaults command, as described in the CLI
Reference Guide.
The mirrored configuration retrieved by this controller from the partner controller has a configuration level that
is too high for the firmware in this controller to process. The local flash configuration will be used instead.
Recommended actions:
The current controller that logged this event probably has down-level firmware. Update the firmware in
the down-level controller. Both controllers should have the same firmware versions.
When the problem is resolved, event 20 is logged.
The partner controller does not have a mirrored configuration image for the current controller, so the current
controller's local flash configuration is being used.
This event is expected if the other controller is new or its configuration has been changed.