10. Instructions for changing the X-gearing assembly

1. Disconnect the laser from mains.
2. Open right and left cover from the laser housing.
3. Remove cover from electronic compartment.
4. Mark the position (scribe a line) of the TENSIONING WEDGE and TENSIONING
BOLT on the right side of x-axis. (Fig. 1)
5. Remove the TENSIONING BOLT and TENSIONING WEDGE (Fig. 1). This will
loosen the x-axis main belt.
6. Remove the two screws and the BELT GRIP on the left side of lens holder.
(Fig. 2)