6. Fire the test pulse again.
X ruler check
1. Glue some adhesive tape in the crosspoint and at the endpoints of the rulers.
2. Focus on the rulers
3. Move the engraving head to 0/0 (Engraver>Move laser, X=10, Y=0)
4. Fire the test pulse into the paper until you see a small spot (press test, keep it
pressed then press service)
5. Move the engraving head to the right end.
6. Fire the test pulse again.

Ruler adjustment

When you´ve found that the Y-axis is not parallel to the ruler (inconstant distance
between the upper and lower spot and the y ruler) you´ve to open the t hree philips
screws that fix the Y ruler and shift the ruler until the above mentioned axis check
shows a result that is within tolerance.
After you´ve done that make sure that the X ruler is oriented in an angle of exactly
90° to the Y ruler. If it is not, please open the five Philips screws that fix it and rotate
the ruler until you reach the correct angle. In the next step you´ve to make sure that
the X axis is parallel to the X ruler. If the X ruler check fails adjust the angle position
of the axis.

Rectangularity adjustment of the motion system

1. Please open the three screws on the right and the two on the left side of the X
axis, that connect it to the sliders.
NORMAL.DOT
max
Gespeichert in:G:\Support\Dokumentationen_CDs\8003Speedy\Service Manual\Servicemanual 8003.doc
I N D I V I D U A L M A R K I N G S Y S T E M S
Gespeichert am:2003/03/10
Version 14
Seite 38 von 87

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Speedy c25Speedy c100Speedy c50

Table of Contents