Cisco NCS 4000 Series Troubleshooting Manual page 40

Hide thumbs Also See for NCS 4000 Series:
Table of Contents

Advertisement

TIMING-FPGA-SEU
Step 2
Ensure the send and expected Trail Trace Identifier (TTI) configurations are correct. In case of mismatch,
configurations needs to be aligned. To set the sent and expected TTI values, use the tti [expected | send]
{ascii |
If the condition does not clear, log into the Technical Support Website at
index.html
TIMING-FPGA-SEU
Default Severity: Critical.
Logical Object: None
TIMING-FPGA-single error upset alarm.
Clear the TIMING-FPGA-SEU Alarm
Procedure
This alarm is automatically cleared by the system, when the Timing-FPGA is upgraded to latest supported
version.
If the condition does not clear, log into the Technical Support Website at
support/index.html
TIMING-ISOLATED-RACK
Default Severity: Critical.
Logical Object: ECU0
TIMING-ISOLATED-RACK alarm occurs when all the TE ports on a rack are down, causing isolation from
timing perspective from all other racks in the MC system.
Clear the TIMING-ISOLATED-RACK Alarm
Procedure
Step 1
Verify that the isolated node is expected as per the topology.
Step 2
Check the physical TE port connections.
Step 3
Check the physical connections between the nodes.
If the condition does not clear, log into the Technical Support Website at
index.html
Alarms Troubleshooting Guide for Cisco NCS 4000 Series
26
dapi
| hex |
operator-specific | sapi } command.
for more information or call Cisco TAC (1 800 553-2447).
for more information or call Cisco TAC (1 800 553-2447).
for more information or call Cisco TAC (1 800 553-2447).
Alarm Management
http://www.cisco.com/c/en/us/support/
http://www.cisco.com/cisco/web/
http://www.cisco.com/c/en/us/support/