Alarm Management
ODUk-BDI-PM
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
ODUk-BDI-PM (Backward Defect Indication) alarm occurs when the BDI bit in the SM/TCMi/PM overhead
field is "1" for 5 consecutive frames.
Clear the ODUk BDI PM Alarm
Procedure
Change the BDI bit in the SM/TCMi/PM overhead field to "0" for 5 consecutive frames.
If the condition does not clear, log into the Technical Support Website at
index.html
ODUk-BIAE
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
ODUk - BIAE (Backward Incoming Alignment Error) alarm occurs if the BEI/BIAE bits in the SM/TCM
overhead field (byte 3, bits 1 to 4) are "1011" for X consecutive frames.
Clear the ODUk-BIAE Alarm
Procedure
Change the BEI/BIAE bits in the SM/TCM overhead field. It should not be equal to "1011" for 3 consecutive
frames.
If the condition does not clear, log into the Technical Support Website at
index.html
ODUk-IAE
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
ODUk - IAE (Incoming Alignment Error) alarm occurs when IAE bit in the SM overhead field is "1" for 5
consecutive frames.
for more information or call Cisco TAC (1 800 553-2447).