Cisco NCS 4000 Series Troubleshooting Manual page 39

Hide thumbs Also See for NCS 4000 Series:
Table of Contents

Advertisement

Alarm Management
Clear the TE-LOS Alarm
Procedure
Step 1
Check the physical TE port connections.
Step 2
Verify that the TE port status is not ADMIN-DOWN.
Step 3
Verify the TE port configuration.
If the condition does not clear, log into the Technical Support Website at
index.html
TE-PORT-UNAVAILABLE
Default Severity: Major ( when only BACKUP TE-PORT is down) and Critical ( when both MASTER TE
port and BACKUP TE-port are down)
Logical Object: ECU0
TE-PORT-UNAVAILABLE alarm occurs when the physical TE port is unavailable or is not connected.
Clear the TE-PORT-UNAVAILABLE Alarm
Procedure
This alarm indicates connectivity issue. Check the connections between TE ports.
If the condition does not clear, log into the Technical Support Website at
index.html
TIM
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Object: PORT
Trail Trace Identifier Mismatch (TIM) alarm occurs when the expected TTI string does not match the received
TTI trace string. Section Trace Mode must be set to manual for this alarm to occur.
Clear the TIM Alarm
Procedure
Step 1
Ensure that the physical fibers are correctly configured and properly connected.
for more information or call Cisco TAC (1 800 553-2447).
for more information or call Cisco TAC (1 800 553-2447).
http://www.cisco.com/c/en/us/support/
http://www.cisco.com/c/en/us/support/
Alarms Troubleshooting Guide for Cisco NCS 4000 Series
Clear the TE-LOS Alarm