Clear the ODUk IAE Alarm
Clear the ODUk IAE Alarm
Procedure
Change the IAE bit in the SM overhead field to "0" for 5 consecutive frames.
If the condition does not clear, log into the Technical Support Website at
index.html
ODUk-LCK-PM
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
ODUk-LCK (Locked) alarm occurs when the upstream connection is locked, and no signal is passed through.
Clear the ODUk LCK PM Alarm
Procedure
Unlock the upstream connection to pass the signal by deleting the shutdown condition (OOS, DSBLD) on
the resource or along the fiber.
If the condition does not clear, log into the Technical Support Website at
index.html
ODUk-OCI-PM
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
ODUk-OCI (Open Connection Indication) alarm occurs when the upstream signal is not connected to a trail
termination source or incase of incomplete intermediate configurations in the ODUk path. This alarm can also
occur during the ODUk path teardown, where one (or more) ODUk hardware along the path was not removed
from the configuration.
Clear the ODUk-OCI-PM Alarm
Procedure
Check for missing or incomplete configurations on the ODUk path towards the upstream direction of the
connected fiber. Complete the configurations as required.
Alarms Troubleshooting Guide for Cisco NCS 4000 Series
16
for more information or call Cisco TAC (1 800 553-2447).
for more information or call Cisco TAC (1 800 553-2447).