OTUk-LOM
If the condition does not clear, log into the Technical Support Website at
index.html
OTUk-LOM
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Object: PORT
LOM (Loss of Multiframe) alarm occurs when the multiframe alignment process is in the out-of-multiframe
(OOM) state for 3 milliseconds.
Clear the OTUk LOM Alarm
Procedure
Keep the multiframe alignment process in the in-multiframe (IM) state for 3 millisecond.
If the condition does not clear, log into the Technical Support Website at
index.html
OTUk-SD
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
This alarm occurs when the quality of the signal is so poor that the bit error rate on the incoming optical line
has crossed the signal degrade threshold.
Clear the OTUk SD Alarm
Procedure
Check if the cable is connected properly. Bent or damaged cables lead to signal loss. Replace the cable, if
required, to clear the alarm.
If the condition does not clear, log into the Technical Support Website at
index.html
OTUk-SF
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Alarms Troubleshooting Guide for Cisco NCS 4000 Series
20
for more information or call Cisco TAC (1 800 553-2447).