Alarm Management
If the condition does not clear, log into the Technical Support Website at
index.html
ODUk-SD-PM
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
ODUk-SD-PM (Signal Degrade) alarm occurs when the quality of signal is so poor that the Bit Error Rate
(BER) on the incoming optical line passed the signal degrade threshold.
Clear the ODUk SD PM Alarm
Procedure
Check if the cable is connected properly. Bent or damaged cables lead to signal loss. Replace the cable, if
necessary.
If the condition does not clear, log into the Technical Support Website at
index.html
ODUk-SF-PM
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
Hardware and software both can generate ODUk-SF-PM alarm based on the summarization of TIM, LCK,
and AIS alarms.
Clear the ODUk SF PM Alarm
Procedure
ODUk SF alarm gets cleared when none of the defects, TIM, LCK or AIS exist.
If the condition does not clear, log into the Technical Support Website at
index.html
ODUk-TIM-PM
Default Severity: Major (MJ), Service-Affecting (SA)
for more information or call Cisco TAC (1 800 553-2447).