Alarm Management
• Standard
• Enhanced
• Enhanced 1.4
• Enhanced 1.7
• 20% High Gain FEC
• 7% High Gain FEC
If the condition does not clear, log into the Technical Support Website at
index.html
FPD-NEED-UPGRADE
Default Severity: Major (MJ), Non-Service-Affecting (NSA)
Logical Object: EQPT
The FPD-NEED-UPGRADE alarm is raised when one or more FPDs are not in current state and require
upgrade.
Clear the FPD Alarm
Procedure
Upgrade all the FPDs to CURRENT state. Use the upgrade hw-module location location fpd fpd-name
command.
If the condition does not clear, log into the Technical Support Website at
index.html
GFP-UP-MISMATCH
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Object: PORT
GFP-UP-MISMATCH alarm is raised when the accepted user payload (UPI) is different from the expected
UPI.
for more information or call Cisco TAC (1 800 553-2447).
for more information or call Cisco TAC (1 800 553-2447).
http://www.cisco.com/c/en/us/support/
http://www.cisco.com/c/en/us/support/
Alarms Troubleshooting Guide for Cisco NCS 4000 Series