Adjusting The Dip Switch Settings On The Mm20-A8A89999Sahh Media Module - Hirschmann MICE MS20-0800 Series User Manual

Industrial ethernet switch
Hide thumbs Also See for MICE MS20-0800 Series:
Table of Contents

Advertisement

OFF ON
4
5
6
7
8
Figure 15: 3-pin DIP switch on the MICE basic module MS20/MS30-...E...
1 - Switch 1, position ON, Function: Redundancy Manager (RM)
2 - Switch 2, position ON, Function: Mod. 1 Port 1 & Mod. 2 Port 1
3 - Switch 3, position ON, Function: Stand-by
4 - Switch 1, position OFF, Function: -
5 - Switch 2, position OFF, Function: Ring Port: Mod. 1 Port 1 & 2
6 - Switch 3, position OFF, Function: -
7 - Switch position OFF
8 - Switch position ON
 Before starting operation of the device, check whether the default settings
of the DIP switch correspond to your requirements.
2.1.7
Adjusting the DIP switch settings on the
MM20-A8A89999SAHH media module
With the 3-pin DIP switch in the bottom panel of the MM20-A8A89999SAHH
media module, you enter settings for the SQE test function and for monitoring
the DTE voltage.
Note: Before starting operation, check whether the device in question
operates the transceiver with or without an SQE test.
 Before starting operation of the device, check whether the default settings
of the DIP switch correspond to your requirements.