Setting Up The Safety Controller - Omron G9SP-N20S Network Connection Manual

Safety controller
Hide thumbs Also See for G9SP-N20S:
Table of Contents

Advertisement

7.2. Setting Up the Safety Controller

Set up the Safety Controller.
7.2.1.
Installing the Option Board
Install the Option Board.
Precautions for Correct Use
Make sure that the power supply is OFF when you install.
1
Confirm that the power supply to
the Safety Controller is OFF.
2
Remove the cover of the option
board slot, and install the
RS-232C option board
(CP1W-CIF01).
RS-232C communications
settings of the Safety Controller
are as follows and cannot be
changed.
•RS-232C communications
setting (fixed)
Baud rate: 9,600 bps
Data length: 8 bits
Stop bits: 1 bit
Parity: E (Even parity)
3
Connect the serial cable
(RS-232C) to the Safety
Controller as shown on the right.
Connect the expansion I/O
connecting cable to the Safety
Controller.
Connect the 24VDC(+) line to
terminal V1 of the Safety
Controller, and the GND line to
terminal G1.
4
Turn ON the power supply to the
Safety Controller.
(Front of Safety Controller)
(RS-232C Option Board)
24VDC power supply
Serial Cable
7. Connection Procedure
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nj seriesG9sp series

Table of Contents