59.1 SPN 651/FMI 14
This diagnosis is typically an open circuit, short to ground or short to power.
59.1.1
Open Circuit, Short to Ground or Short to Power Check
Check as follows:
1. Check for multiple codes.
[a] If fault code 168/1 is active in addition to other codes, service 168/1 first.
Refer to section 32.2.
[b] If fault 652/14 and 653/14 are active in addition to 651/14, go to step 2.
[c] If only fault code 651/14 is active, go to step 10.
2. Turn the ignition OFF.
3. Disconnect the Front Injector Harness 12–pin connector.
4. Inspect the Front Injector Harness 12–pin connector for bent or spread pins, inspect the
connector seal for damage (signs of water or oil intrusion).
[a] If the water or oil intrusion, bent or spread pins are found, repair as necessary.
Refer to section 59.1.1.1.
[b] If connector shows no signs of damage, go to step 5.
5. Measure the resistance between pin 10 and pins 1 on the valve cover side of the Front
Injector Harness. If using J-48671–10, measure between injector #1 pins 1 and 2.
[a] If the resistance is greater than 3 Ω, replace the under valve cover injector
harness.Refer to section 59.1.1.1.
[b] If the resistance is less than 3 Ω, go to step 6.
6. Disconnect the MCM 120–pin connector.
7. Measure the resistance between pin 11of the MCM 120–pin connector and pin 10 of the
Front Injector Harness 12–pin connector. See Figure 59-1.
[a] If the resistance is less than 3 Ω, go to step 8.
[b] If the resistance is greater than 3 Ω, repair the open between pin 11 of the MCM
120–pin connector and pin 10 of the Front Injector Harness 12–pin connector.
Refer to section 59.1.1.1.
8. Disconnect the negative battery cable.
9. Measure the resistance between the positive battery post and pin 11of the MCM 120–pin
connector.
[a] If the resistance is greater than 3 Ω, contact the Detroit Diesel Customer Support
Center at 313–592–5800 for MCM replacement authorization.
All information subject to change without notice.
Copyright © 2007 DETROIT DIESEL CORPORATION
SERIES 60 DDEC VI TROUBLESHOOTING GUIDE
59-3
Need help?
Do you have a question about the EPA07 Series 60 DDEC VI and is the answer not in the manual?