Description
Monitored Parameter
Typical Enabling Conditions
Monitor Sequence
Execution Frequency
Typical Duration
Description
Monitored Parameter
Typical Enabling Conditions
Monitor Sequence
Execution Frequency
Typical Duration
Description
Monitored Parameter
Typical Enabling Conditions
Monitor Sequence
Execution Frequency
Typical Duration
Description
Monitored Parameter
Typical Enabling Conditions
Monitor Sequence
Execution Frequency
Typical Duration
All information subject to change without notice.
Copyright © 2007 DETROIT DIESEL CORPORATION
SERIES 60 DDEC VI TROUBLESHOOTING GUIDE
SPN 3660/FMI 6
Injector Cylinder #2 Spill Control Valve ("Amplifier"), Valve Shorted
Circuit, driver status = short circuit
Fuel Injector - Spill Control Valve Current EUI Cyl 2
Always Enabled
None
Always Enabled
< 5 seconds
SPN 3660/FMI 14118.1
Injector Cylinder #2 Spill Control Valve Abnormal Operation,
Verifies appropriate peak current is achieved in specified time duration
Fuel Injector Spill Solenoid Cyl 2
When there is no circuit continuity on relevant cylinder or injector bank
None
Always Enabled
< 5 seconds
SPN 3661/FMI 6
Injector Cylinder #3 Spill Control Valve ("Amplifier"), Valve Shorted
Circuit, driver status = short circuit
Fuel Injector - Spill Control Valve Current EUI Cyl 3
Always Enabled
None
Always Enabled
< 5 seconds
SPN 3661/FMI 14119.1
Injector Cylinder #3 Spill Control Valve Abnormal Operation,
Verifies appropriate peak current is achieved in specified time duration
Fuel Injector Spill Solenoid Cyl 3
When there is no circuit continuity on relevant cylinder or injector bank
None
Always Enabled
< 5 seconds
18-31