81.3 SPN 1071/FMI 5
This fault code indicates that there is an open circuit.
81.3.1
Open Circuit Check
Check as follows:
1. Check for multiple codes.
[a] If SPN 647/5, SPN 1072/5 and SPN 1071/5 are active repair the open in between
the pin 91 of the 120–pin MCM connector and the fan and the Jake Brake solenoids.
Refer to section 81.3.1.1.
[b] If only SPN 1071/5 is active, go to step 2.
2. Disconnect the fan control solenoid connector.
3. Turn the ignition ON (key On, engine OFF).
4. Measure the voltage between pin 1 and 2 of the fan control solenoid connector.
[a] If the voltage is less than 11.5 volts, go to step 5.
[b] If the voltage is between 11.5 and 13.5 volts, replace the fan control solenoid.
Refer to section 81.3.1.1.
5. Measure the voltage between pin 2 of the fan control solenoid connector and ground.
[a] If the voltage is less than 11.5 volts, repair the open between pin 2 of the fan control
solenoid connector and pin 91 of the 120–pin MCM connector. Refer to section
81.3.1.1.
[b] If the voltage is greater than 11.5, repair the open between pin 1 of the fan control
solenoid connector and pin 33 of the 120–pin MCM connector. Refer to section
81.3.1.1.
81.3.1.1
Verify Repairs
Verify repairs as follows:
1. Turn ignition OFF.
2. Reconnect any electrical connections that were disconnected to perform the diagnosis.
3. Clear codes with DDDL 7.0 or latest version.
4. Start and bring engine up to operating temperature (over 140°F/60°C).
5. Verify operation is satisfactory and no warning lamps illuminate. If warning lamps
illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel
Customer Support Center at 313–592–5800.