GENERAL INFORMATION
Specifications*
Pipe Size
Power
Sensor
Materials
Housing
Tubing/Fitting/Sensor Housing
Rotor
Shaft
Bearings
O-Ring (15x/25x only)
Valve Assembly for:
Fitting Size Required
Maximum
Pressure
Temperature
Flow Velocity
Accuracy
Output Transistor Maximum Current Sinking
Cable
Environmental
Regulatory
*Specifications subject to change. Please consult our website for the most current data (www.seametrics.com).
Kynar is a registered trademark of Arkema, Inc.
Seametrics • 253.872.0284
3" to 40"
Low Power: 6-36 Vdc/< 2 mA
Low Power: Digital Magnetoresistive
Powder-coated cast aluminum
Brass, PVC, or 316 Stainless Steel
PVDF (Kynar®)
Kynar® /Tungsten Carbide (Kynar® /Ceramic or Kynar®/Silicon Carbide optional)
Ruby jewel
EDPM
IP11x/21x (Brass/SS)
IP11x/21x (PVC)
None
None
1.5" FNPT
2" FNPT
Brass/SS: 200 psi (14 bar)
Brass/SS: 200˚ F (93˚ C)
0.3 to 30 ft/sec (0.9 to 9.14 m/sec)
± 1.5% of full scale
150mA (low power version only)
#22 AWG 3-con, 18' (6m); 2,000' (610m) maximum cable run Note: 50' (15m) maximum for battery powered
or micropowered versions.
See meter mounted electronic specification for rating.
Mark
Page 4
IP100/200 SERIES INSTRUCTIONS
Micropowered (-04 Option): 3.1-16 Vdc/60 μA @ 3.6 Vdc
Micropowered (-04 Option): Giant Magnetoresistance (GMR)
IP15x/25x (Brass/SS)
Bronze (316SS optional)
2" FNPT
PVC: 150 psi (10 bar)
PVC: 130˚ F (55˚ C)
IP15x/25x (PVC)
Uses gate valve
2" FNPT
seametrics.com
Need help?
Do you have a question about the IP100 Series and is the answer not in the manual?
Questions and answers