Cisco ASA Series Cli Configuration Manual page 2034

Software version 9.0 for the services module
Hide thumbs Also See for ASA Series:
Table of Contents

Advertisement

Feature History for SNMP
Table 1-7
Feature History for SNMP (continued)
Platform
Feature Name
Releases
SNMP traps and
8.4(1)
MIBs
IF-MIB ifAlias OID
8.2(5)/8.4(2)
support
ASA Services
8.5(1)
Module (ASASM)
SNMP traps
8.6(1)
Cisco ASA Series CLI Configuration Guide
1-32
Feature Information
Supports the following additional keywords: connection-limit-reached, cpu
threshold rising, entity cpu-temperature, entity fan-failure, entity power-supply,
ikev2 stop | start, interface-threshold, memory-threshold, nat packet-discard,
warmstart.
The entPhysicalTable reports entries for sensors, fans, power supplies, and related
components.
Supports the following additional MIBs: CISCO-ENTITY-SENSOR-EXT-MIB,
CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-PROCESS-MIB,
CISCO-ENHANCED-MEMPOOL-MIB,
CISCO-L4L7MODULE-RESOURCE-LIMIT-MIB, DISMAN-EVENT-MIB,
DISMAN-EXPRESSION-MIB, ENTITY-SENSOR-MIB, NAT-MIB.
Supports the following additional traps: ceSensorExtThresholdNotification,
clrResourceLimitReached, cpmCPURisingThreshold, mteTriggerFired,
natPacketDiscard, warmStart.
We introduced or modified the following commands: snmp cpu threshold rising,
snmp interface threshold, snmp-server enable traps.
The ASA now supports the ifAlias OID. When you browse the IF-MIB, the ifAlias
OID will be set to the value that has been set for the interface description.
The ASASM supports all MIBs and traps that are present in 8.4(1), except for the
following:
Unsupported MIBs in 8.5(1):
CISCO-ENTITY-SENSOR-EXT-MIB (Only objects under the
entPhySensorTable group are supported).
ENTITY-SENSOR-MIB (Only objects in the entPhySensorTable group are
supported).
DISMAN-EXPRESSION-MIB (Only objects in the expExpressionTable,
expObjectTable, and expValueTable groups are supported).
Unsupported traps in 8.5(1):
ceSensorExtThresholdNotification (CISCO-ENTITY-SENSOR-EXT-MIB).
This trap is only used for power supply failure, fan failure, and high CPU
temperature events.
InterfacesBandwidthUtilization.
Supports the following additional keywords for the ASA 5512-X, 5515-X, 5525-X,
5545-X, and 5555-X: entity power-supply-presence, entity power-supply-failure,
entity chassis-temperature, entity chassis-fan-failure, entity
power-supply-temperature.
We modified the following command: snmp-server enable traps.
Chapter 1
Configuring SNMP

Advertisement