2.2.3.4.2 Connecting The Dc Power Supply; Figure 2-26: Dc Power Terminal Block Screw Connector; Figure 2-27: Dc Power Terminal Block Crimp Connector - AudioCodes Mediant 1000 MSBG Installation And Configuration Manual

Enhanced media gateway and sba for microsoft lync
Hide thumbs Also See for Mediant 1000 MSBG:
Table of Contents

Advertisement

2.2.3.4.2 Connecting the DC Power Supply

The device can connect to a DC power supply using one of the following methods:
DC terminal block with a screw connection type.
DC terminal block with a crimp connection type.
To connect power using a DC terminal block screw connector:
1.
Create a DC cable by inserting two 14-16 AWG insulated wires into the supplied terminal
block adaptor (refer to the figure below), and then fasten the two screws, each one located
directly above each wire.
2.
Connect the two insulated wires to the correct DC power supply. Ensure that the connections
to the DC power supply maintain the correct polarity.
3.
Insert the terminal block into the DC inlet located on the device's rear panel.
To connect power using a DC terminal block crimp connector:
1.
Remove the DC adaptor (screw connection type) that is attached to the device's rear panel.
2.
Connect the two insulated wires to the correct DC power supply. Ensure that the connections
to the DC power supply maintain the correct polarity.
3.
Insert the terminal block into the DC inlet located on the device's rear panel.
AudioCodes Enhanced Media Gateway

Figure 2-26: DC Power Terminal Block Screw Connector

Figure 2-27: DC Power Terminal Block Crimp Connector

36
Survivable Branch Appliance
Document #: LTRT-18206