Osn3 Modules (For Sba Media Gateway); 2.1.1.3.1 Osn3 Module; Figure 2-3: Osn3 Module Ports; Table 2-3: Osn3 Specifications - AudioCodes Mediant 1000 MSBG Installation And Configuration Manual

Enhanced media gateway and sba for microsoft lync
Hide thumbs Also See for Mediant 1000 MSBG:
Table of Contents

Advertisement

Installation and Configuration Manual
2.1.1.3

OSN3 Modules (for SBA Media Gateway)

The OSN3 platform consists of two main AMC modules:
OSN3, providing the port connector interfaces (refer to Section
HDMX, providing the hard-disk drive (refer to Section
The table below lists the specifications of the OSN3 server platform:
Parameter
CPU
RAM Memory
Storage
Bus/Chipset
L2 Cache
Interfaces

2.1.1.3.1 OSN3 Module

The OSN3 module connector ports are shown in the figure below and described in
Table
2-4.
Item #
1
RJ-45 port for RS-232 serial interface (COM1)
2
RJ-45 port for Gigabit Ethernet. The interface provides automatic detection and switching
between 10Base-T, 100Base-TX and 1000Base-T data transmission (Auto-Negotiation).
Auto-wire switching for crossed cables is also supported (Auto-MDI/X).
3
USB 2.0 port
4
Insertion/extraction handle
SBA for Microsoft Lync

Table 2-3: OSN3 Specifications

Intel® Core™ 2 Duo 1.5 GHz processors L7400 with Intel 3100 Chipset (64-bit)
2 G or 4 G DDR2 with ECC
Single or Dual hard-disk drive of 80 G SATA
64 Bit
2 M
Gigabit Ethernet
USB 2.0 via Connection Module
RS-232 COM

Figure 2-3: OSN3 Module Ports

Table 2-4: OSN3 Module Component Description

2.1.1.3.2
Specification
Description
19
2. Hardware Installation
2.1.1.3
on page 19)
on page 22)
December 2010

Advertisement