Figure 3 - Coraid Parallel Path Utilization W/O Mpio - Avaya VSP 9000 Technical Configuration Manual

Avaya virtual services platform with coraid etherdrive srx-series storage appliances
Table of Contents

Advertisement

6) Each PC should mount a different RAID array:
mount -t ext3 /dev/<device> /mnt/coraid
7) Confirm that the RAID is reachable to the drive and write a file to it with the following command:
cd /mnt/coraid;touch foo
The Coraid HBAs have two ports and utilize every available port between the server initiator and target
(see Figure 3). The HBAs have Coraid firmware to manage the Ethernet SAN and cannot be configured
as a regular network card.
Coraid EtherDrive SRX-Series storage appliances do not support MLT or LACP. Coraid HBAs
load balance and provide high performance link redundancy without the need for port
aggregation, bonding, or traditional SAN MPIO software.
1
2
Write #1a
Write #1b
Write #1c
Ethernet
AoE
Data Segment
For Coraid HBA support information, go to Coraid EtherDrive: Ethernet SAN for Virtualization,
Cloud, and Enterprise Storage at http://www.coraid.com/support/customer_support.
Dec 2010
64K IO Transfer
3
4
5
6
7
Write #2a
Write #2b
Write #2c
Write #1d
Write #2d
CRC
Figure 3 – Coraid parallel path utilization w/o MPIO
VSP 9000 with Coraid EtherDrive SRX-Series
Storage Appliances TCG
8
Path0
Port 0
Port 0
Path1
Port 1
Port 1
Initiator
Path2
Port 2
Port 2
Path3
Port 3
Port 3
avaya.com
AoE 8K block (data)
Array
19

Advertisement

Table of Contents
loading

Table of Contents