JVC DLA-VS4010 Instructions Manual page 56

D-ila projector
Table of Contents

Advertisement

Parameters used for the data format
The following 2 types of parameters are used for command and response data:
(1) ON/OFF (2) Special Parameter
Each parameter is as follows:
(1) ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character
0
1
(2) Special parameters
Operation mode parameters
Character
0
1
2
3
4
DHCP client parameters
Character
0
1
IP address parameters
Display the IP address using the dot ("." (2HE)) delimiter.
Example: "192.168.0.10"
External control command table
Function
Command
Power
U0F
Hide
U00
Operation Mode
UA0
DHCP Client
UD2
IP Address
UD3
Network Restart
UDC
MEMO
After configuring "DHCP Client" and "IP Address", execute "Network Restart".
0
56
Hex
30
31
Hex
30
31
32
33
34
Hex
30
31
Setting
Power On
ELSE
X (OFF)
X (ON)
-
X
-
-
X
X
X
X
X
X
Standby state
Power ON state
Cooling state
Emergency cooling state
Emergency state
DHCP
STATIC IP
Asking
Power On
ELSE
-
-
-
X
X
X
X
X
X
X
X
X
Meaning
OFF
ON
Meaning
Meaning
Data Type
ON/OFF
Special Parameter
-
X
-
X
-
Standby...
-
DHCP...
-
192.168. ...
-
"0" Fixed