Direct Suction; Taking Out Of Operation - Kranzle LX 2000 Operating Manual

Table of Contents

Advertisement

Direct suction

Direct water extraction
Due to the suction capacity of its high pressure pump (up to 2.5 m suction height,
max. hose length 3 m) this high pressure cleaner can suck in water for cleaning
purposes from separate containers or ponds.
Prior to starting the first suction the high pressure pump and the
suction hose has to be filled with water!
Note
Depending on the water quality it may occur after a prolonged standstill
that the valves get sticky. Consequently the high pressure cleaner cannot
properly suck in water from a container. In this case connect a hose with
pressurized water to the pump inlet. Having started the high pressure
cleaner the pressurized water opens the valves and the machine resumes
sucking in water from the container. Now you can carry on with your
cleaning task as usual.
22
1.
Mount suction hose with suction filter
(Item no.: 150383).
2.
Put filled suction hose into the water-
filled container and start the cleaning
job. Use clean water only! Never suck
in water containing chlorine! Do not
suction air!

Taking out of operation

1.
Switch off the high pressure cleaner
2. Cut off the water supply
3.
Open the safety trigger gun catch briefly until the pressure is released
4. Apply safety catch on the trigger gun
5.
Remove high pressure hose and safety trigger gun
6. Emptying high pressure pump: Hold high pressure hose and switch
motor on until water jet stops escaping at the outlet.
7.
Pull the plug from the socket
8. Clean high pressure hose and wind up without loops, fix hose drum
9. Clean and wind up the power supply cable
10. Clean the water inlet sieve
11. Apply locking brake
12. Store high pressure cleaners in frost-free rooms in winter
Frost protection
For protecting the high-pressure cleaner against frost please empty it completely.
Separate high-pressure cleaner from water supply and switch it on. By opening
the trigger gun the high-pressure pump presses water out of the high-pressure
cleaner. However, do not allow the device to operate without water for more
than one minute.