Error Codes are subject to change without any prior written notice.
ERROR CODES
PAN Er
TILT Er
Cyan Color Wheel Er
Magenta Color Wheel
Er
Yellow Color Wheel Er
CTO Color Wheel Er
Speed of CMY Wheel Er
Color Wheel Er
Gobo Wheel 1 Er
Gobo Rot. 1 Wheel Er
Fixed Gobo Wheel Er
Rotating Prim Er
Iris Er
Focus Er
Zoom Er
Blade 1 Er
Blade 2 Er
Blade 3 Er
Blade 4 Er
g4UFan1 Error
g4UFan2 Error
g5UFan1 Error
g5UFan2 Error
Temp Error
ELATION SATURA PROFILE
E R R O R C O D E S
Movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a motor failure (defective motor or a defective motor IC
drive on the main PCB). This error may also be displayed if the
head/yoke was blocked during a reset function.
Movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a motor failure (defective motor or a defective motor IC
drive on the main PCB).
Error information from JB1 port on 4U01 PCB.
Displayed as 4U_Fan1 RPM <1000.
Error information from JB2 port on 4U01 PCB.
Displayed as 4U_Fan2 RPM <1000.
Error information from JB2 port on 5U01 PCB.
Displayed as 5U_Fan1 RPM <1000.
Error information from JB2 port on 5U01 PCB.
Displayed as 5U_Fan2 RPM <1000.
Temperature <37.4°F (3°C) or >320°F (160°C).