SYSTEM MENU CHANGE WITH SOFTWARE UPDATE VERSION ≥1.0.10
See highlighted menu items below which have been updated with this software update.
MAIN MENU
SUB MENU
Set Dmx Address
Dmx Value
FUNCTION
Slave Mode
Auto Program
Time Information
INFORMATION
Temperature Info
Ethernet IP
Fan Speed
Software Version
Error Info
Status Settings
Service Setting
PERSONALITY
Fans Control
Display Setting
Temperature C/F
Initial Status
Refresh
Gamma
Select Signal
Set Universe
Reset Default
Features are subject to change without any prior written notice.
OPTIONS / VALUES
A001~AXXX
ALL......
Slave1, Slave2, Slave3
Master / Alone
Current Time
Total Run Time
Last Run Time
LastRun Password
Clear Last Run
Head Temperature
XXX.XXX.XXX.XXX
XXX.XXX.XXX.XXX
1U_Fan1: ~ 5U_Fan2:
1U01: - 7U01:
Error Record 1 ~ Error Record 10
Address via DMX
No DMX Status
Pan Reverse
Tilt Reverse
Pan Degree
Feedback
Movement Speed
Fast Mode
Hibernation
Dimmer Mode
Password
RDM PID
Ethernet IP
Ethernet Mask IP
Clear Err. Info
Auto, Silent
Shutoff Time
Display Reverse
Key Lock
Celsius/Fahrenheit
PAN =XXX
1200, 900-1500, 2500, 4000, 5000, 10000,
15000, 20000, 25000 (Hz)
Gama = 2.0, 2.2, 2.4, 2.8
DMX Only
Art-Net
sACN
000 - 32767
ON/OFF
(Default Settings in BOLD)
XXXX (Hours)
XXXX (Hours)
XXXX (Hours)
Password=XXX
ON / OFF
XXX C° / F °
XXX RPM
≥V1.0.10
ON/OFF
Close Shutter / Hold /
Auto Program
ON/OFF
ON/OFF
630/540
ON/OFF
Speed 1 ~ 4
ON/OFF
OFF, 01M~99M, 15M
Standard, Stage, TV,
Architectural, Theatre
Password=050
XXXXX
XXX . XXX . XXX . XXX
XXX . XXX . XXX . XXX
ON/OFF
02~60m 05m
ON/OFF
ON/OFF
Password=011
21
DESCRIPTION
DMX Address Setting
DMX Value Display
Slave Setting
Auto Program
Fixture Run Time From Power ON
Fixture Total Run Time
Clear Fixture Last Run Time
Password 038
Clear Fixture Last Run Time
Temperature in Fixture Head
Fixture IP Address
Fan Speeds
Software Version
Pan....
Address Via DMX
Auto Run If No DMX
Pan Reverse Movement
Tilt Reverse Movement
Pan Degree Select
Movement Feedback
Movement Mode Select
Fast Mode Select
Stand By Mode
Set Dimmer Curve Mode
Service Password
RDM PID Code (PSWD Required)
Ethernet IP (PSWD Required)
Ethernet Mask IP (PSWD Required)
Clear Error Info (PSWD Required)
Select Fans Mode
Display Shut Off Time
Display Reverse 180º
Key Lock
Temperature Switch Between C˚/ F˚
Initial Effect Position
Refresh Frequency Rate Setting
Gamma Setting
DMX Only
Select Art-Net
Select sACN
Set ArtNet Universe
Restore Factory Settings
(PSWD Required)