Electrical; Electrical Supply - Sirius Range Hoods SU 207 Installation And Use Manual

Contemporary wall range hoods
Table of Contents

Advertisement

Maximum Run
6" or 3 1/4 x 10" duct
Deduct
Each 90 elbow used
Each 45 elbow used
Each 6" or 3 1/4 x 10" duct
Transition used
Each 3'1/4 x 10" to 6"
Transition used
Side Wall with damper
Roof Cap
Figure 2
WARNING: All electrical work must
be
performed
by
electrician.
Please ensure that the appropriate
electrical codes or prevailing local
building codes and ordinances are
adhered to.
Ensure that the electricity supply is
disconnected at source. Do not use
an extension cord or adapter plug
with this appliance.
This appliance must be grounded.
Connect to a properly grounded
branch circuit, protected by a 15
amp circuit breaker.
hood is 100'. Calculate your duct run
by measuring linear feet and adding
100 FT
the elbows, transitions and caps
based on the table alongside.
15FT
The ducting connection to the hood
9FT
must be in line with the central
vertical axis of the range hood 1"
1FT
away from the back wall on which
the hood is to be mounted.
5FT
30FT
The 1" is important to enable the
ceiling bracket (as shown in Figure
30FT
2) to pass behind the ductwork
servicing the range hood. Range
hoods may interrupt the proper flow
of combustion gases from fireplaces,
gas furnaces and gas water heaters.
To minimize the risk of drawing
these lethal gases back into the
home, please follow the heating
equipment manufacturers
standards and guidelines carefully.
Refer to NFPA and ASHRAE for
additional information.
E L E C T R I C A L

Electrical Supply

a
qualified
This range hood requires a 120V,
60Hz supply and draws a maximum of
3 amps. The electrical supply to the
range hood should be at least 17"
from the underside of the installed
range hood.
For a typical installation, where the
underside of the range hood will be
30" above the counter top and the
counter top is 36" above the floor
level, the electrical supply should be
94" above floor level and no further
than 3" to the right (as you face the
wall) of the central axis of the range
hood.
safety