Duct Run Calculation; Electrical; Electrical Supply - Sirius Range Hoods SUF1 Installation Instructions Manual

Under cabinet range hoods
Hide thumbs Also See for SUF1:
Table of Contents

Advertisement

at

Duct Run Calculation

The maximum duct run before
effecting the performance of the
hood is 100'. Calculate your duct run
by measuring linear feet and adding
the elbows, transitions and caps
based on the table alongside.
Maximum Run
6" or 3 1/4 x 10" duct
Deduct
Each 90 elbow used
Each 45 elbow used
Each 6" or 3 1/4 x 10" duct
Transition used
Each 3'1/4 x 10" to 6"
Transition used
Side Wall with damper
Roof Cap
WARNING: All electrical work must
be
performed
electrician.
Please ensure that the appropriate
electrical codes or prevailing local
building codes and ordinances are
adhered to.
Ensure that the electricity supply is
disconnected at source. Do not use
an extension cord or adapter plug
with this appliance.
This appliance must be grounded.
Connect to a properly grounded
branch circuit, protected by a 15
amp circuit breaker.
Call 1-800-667-8721 anywhere in the US and Canada
The ducting connection to the hood
must be in line with the central
vertical axis of the range hood 1"
away from the back wall on which
the hood is to be mounted.
Range hoods may interrupt the
proper flow of combustion gases
from fireplaces, gas furnaces and
gas water heaters.
100 FT
To minimize the risk of drawing
these lethal gases back into the
home, please follow the heating
15FT
equipment manufacturers
standards and guidelines carefully.
9FT
Refer to NFPA and ASHRAE for
1FT
additional information.
5FT
30FT
30FT
E L E C T R I C A L

Electrical Supply

by
a
qualified
This range hood requires a 120V,
60Hz supply and draws a maximum of
3 amps. The electrical supply to the
range hood should be at least 17"
from the underside of the installed
range hood.
For a typical installation, where the
underside of the range hood will be
30" above the counter top and the
counter top is 36" above the floor
level, the electrical supply should be
76"" above floor level and no further
than 3" to the right (as you face the
wall) of the central axis of the range
hood.
kitchen::
accessories
Sirius at
U
N
L
I
M
safety
I
T
E
D
www.kitchensource.com
-
2