WARNING: All electrical work must be
performed by a qualified electrician.
Please ensure that the appropriate electri-
cal codes or prevailing local building co-
des and ordinances are adhered to.
Ensure that the electricity supply is di-
sconnected at source. Do not use an ex-
tension cord or adapter plug with this
appliance.
This appliance must be grounded. Con-
nect to a properly grounded branch
circuit, protected by a 15 amp circuit
breaker.
E LE CT RIC AL
Electrical Supply.
This
3amp electrical supply – ensure an ap-
propriately qualified person completes
the electrical hook-up. The connection
point for the electrical supply is at the top
of the unit, therefore the electrical supply
must be run down from the ceiling alon-
gside the ductwork.
All electrical and venting hook-ups must
be in place before commencing installa-
tion of the hood-fan.
appliance
requires
120V/60Hz,
5