OPERATION
DELIMING
07610-004-29-29-D
OPERATING INSTRUCTIONS
To maintain the machine at its optimum performance level, lime and corrosion de-
posits must be removed. The frequency for deliming will be based on water condi-
tions. A deliming solution is available from your chemical supplier. Read and follow
all instructions on the label.
To delime the machine:
1. Disconnect or turn off all chemical feeder equipment.
2. Remove rinse arms and place in sink with deliming solution.
3. Verify the standpipe is in position, turn the machine on, and allow the
machine to complete a fill cycle.
4. Open the door and verify water level is above standpipe. Add deliming
solution per the solution manufacturer's recommendation (the water capacity
of the tank can be verified on the specification page of this manual).
5. Close the door and push the Delime Button on the display.
6. Run the machine for the period of time recommended by the chemical
supplier.
7. Press the Delime Button again and the pump will stop.
8. Open the door and remove the standpipe.
9. Wait five minutes, then inspect the inside of the machine. If the machine is
not delimed, run again.
10. When clean, drain and refill the machine.
11. Run a cycle to remove residual deliming solution.
12. Replace rinse arms.
13. Drain and refill the machine.