SPECIFICATIONS
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual
are for reference and may change without notice
i
DYNATEMP & DYNATEMP VER
Volts
Phase
208
1
230
1
208
3
230
3
460
3
DYNATEMP NB
Volts
Phase
208
1
230
1
208
3
230
3
460
3
DYNATEMP S
Volts
Phase
208
1
230
1
208
3
230
3
460
3
07610-004-29-29-D
On three-phase machines, imbalanced wild leg goes to L3
Also see the Motor Rotation section
Wash
Freq
Motor
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
1.8 A
Wash
Freq
Motor
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
1.8 A
Wash
Freq
Motor
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
5.0 A
60 Hz
1.8 A
ELECTRICAL REQUIREMENTS
NOTICE
Wash
Rinse
Heater
Heater
19.7 A
50.6 A
21.8 A
55.9 A
11.4 A
29.2 A
12.6 A
32.3 A
6.3 A
16.1 A
Wash
Rinse
Heater
Heater
19.7 A
N/A
21.8 A
N/A
11.4 A
N/A
12.6 A
N/A
6.3 A
N/A
Wash
Rinse
Heater
Heater
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Total Load
MCA
75.3 A
76.6 A
82.7 A
84.0 A
45.6 A
46.9 A
49.9 A
51.2 A
24.2 A
24.7 A
Total Load
MCA
24.7 A
26.0 A
26.8 A
28.1 A
16.4 A
17.7 A
17.6 A
18.9 A
8.1 A
8.6 A
Total Load
MCA
5.0 A
6.3 A
5.0 A
6.3 A
5.0 A
6.3 A
5.0 A
6.3 A
1.8 A
2.3 A
MOP
80.0 A
90.0 A
50.0 A
55.0 A
30.0 A
MOP
30.0 A
30.0 A
20.0 A
20.0 A
15.0 A
MOP
15.0 A
15.0 A
15.0 A
15.0 A
15.0 A
6