Jackson Dynatemp Series Installation, Operation And Service Manual page 15

Door-type machines
Table of Contents

Advertisement

INSTALLATION
WATER SUPPLY
CONNECTION
A water hardness test
MUST be performed.
i
Take care not to confuse
static pressure with
flow pressure!
STEAM LINE
CONNECTION
i
PLUMBING
!
CAUTION
07610-004-29-29-D
NOTICE
Read the Plumbing section on the previous page before proceeding
Install the water supply line to the machine using copper pipe. A water shut-off valve
should be installed in the water line between the main supply and the machine to
allow access for service.
If water hardness tests at greater than 3 GPG, install the Scaltrol Water Treatment
system (see the Plumbing Options page) into the water line before the machine's
incoming water connection point. If water hardness tests at 3 GPG or less, install the
water supply line directly to the machine's incoming water connection point.
The water supply line must be capable of 10 ± 2 PSI "flow" pressure at the recommended
temperature indicated on the data plate.
Do not confuse static pressure with flow pressure. Static pressure is the line pressure
in a "no flow" condition (all valves and services are closed). Flow pressure is the
pressure in the fill line when the fill valve is opened during the cycle.
The manufacturer recommends the installation of a pressure regulating valve (PRV)
in the incoming water line to ensure proper flowrate at all times and offers these
devices as options. See the Plumbing Options page. The PRV comes standard on
the DynaTemp VER but ships inside the machine. Click
The manufacturer also recommends the installation of a water hammer arrestor in the
incoming water line and offers these devices as options. See the Plumbing Options
page. This prevents line hammer/hydraulic shock—induced by the solenoid valve as
it operates—from causing damage to the equipment.
DynaTemp S comes with lines to connect the source steam. Connect steam lines to
the machine according to all applicable codes. See machine data plate for information
concerning steam flow pressure.
Click
here
1. Slowly turn on the water supply to the machine after the incoming fill line and drain
line have been installed.
CHECK
2. Check for any leaks and repair as required.
CAUTION! All leaks must be repaired before placing the machine in operation
for the Steam Booster manual.
INSTRUCTIONS
here
for install instructions.