Jackson Dynatemp Series Installation, Operation And Service Manual page 18

Door-type machines
Table of Contents

Advertisement

INSTALLATION
VOLTAGE CHECK
!
CAUTION
i
EXHAUST FAN
SURROUNDING
TEMPERATURE
SETPOINTS
CORNER INSTALL/
FALSE PANEL
07610-004-29-29-D
1. Ensure the power switch is in the OFF position and apply power to the machine.
2. Check the incoming power at the terminal block and ensure it corresponds to
the voltage listed on the data plate. If not, contact a qualified service agency to
examine the problem.
CAUTION! Do not run the machine if the voltage is too high or too low (refer to
applicable electrical codes)
3. Shut off the service breaker and mark it as being for the machine.
4. Advise all proper personnel of any problems and of the location of the service
breaker.
Determine which exhaust fan timer is on the machine and click the instructions icon
below that timer to access programming instructions.
TIMER
This is a commercial machine and reaches temperatures that can exceed those
generated by a residential machine. Surrounding countertops, cabinets, flooring, and
AREA
subflooring must be designed and/or selected with these higher temperatures in
mind.
Any damage to surrounding area caused by heat/moisture to materials that
NOTICE
are not recommended for higher temperatures will not be covered under
warranty or by the manufacturer
The temperature setpoints on this machine have been set at the factory. They
should only be adjusted by an authorized service agent.
The manufacturer offers an optional False Panel Kit for corner installations.
Click
here
for corner install and false panel instructions.
DynaTemp False Panel Kit
05700-004-44-38
INSTRUCTIONS
11