u-blox LARA-R2 series System Integration Manual page 71

Lte cat 1 / egprs modules
Hide thumbs Also See for LARA-R2 series:
Table of Contents

Advertisement

2.2.1.4
Guidelines for VCC supply circuit design using a rechargeable Li-Ion or Li-Pol battery
Rechargeable Li-Ion or Li-Pol batteries connected to the VCC pins should meet the following prerequisites to
comply with the module VCC requirements summarized in Table 6:
Maximum pulse and DC discharge current: the rechargeable Li-Ion battery with its related output circuit
connected to the VCC pins must be capable of delivering a pulse current as the maximum peak / pulse
current consumption during Tx burst at maximum Tx power specified in LARA-R2 series Data Sheet [1] and
must be capable of extensively delivering a DC current as the maximum average current consumption
specified in LARA-R2 series Data Sheet [1]. The maximum discharge current is not always reported in the
data sheets of batteries, but the maximum DC discharge current is typically almost equal to the battery
capacity in Amp-hours divided by 1 hour.
DC series resistance: the rechargeable Li-Ion battery with its output circuit must be capable of avoiding a
VCC voltage drop below the operating range summarized in Table 6 during transmit bursts.
2.2.1.5
Guidelines for VCC supply circuit design using a primary (disposable) battery
The characteristics of a primary (non-rechargeable) battery connected to VCC pins should meet the following
prerequisites to comply with the module VCC requirements summarized in Table 6:
Maximum pulse and DC discharge current: the non-rechargeable battery with its related output circuit
connected to the VCC pins must be capable of delivering a pulse current as the maximum peak current
consumption during Tx burst at maximum Tx power specified in LARA-R2 series Data Sheet [1] and must be
capable of extensively delivering a DC current as the maximum average current consumption specified in
LARA-R2 series Data Sheet [1]. The maximum discharge current is not always reported in the data sheets of
batteries, but the max DC discharge current is typically almost equal to the battery capacity in Amp-hours
divided by 1 hour.
DC series resistance: the non-rechargeable battery with its output circuit must be capable of avoiding a
VCC voltage drop below the operating range summarized in Table 6 during transmit bursts.
UBX-16010573 - R02
LARA-R2 series - System Integration Manual
Objective Specification
Design-in
Page 71 of 148

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lara-r204Lara-r211

Table of Contents