Installation
b
e
f
i
h
Figure 2.2 Axial Fastening
Type
a
b
min
OGD-30
30
120
OGD-35
35
120
OGD-40
40
120
Table 2.3 Dimensions
1) Key length required for b
. Adapt the key length according to the shaft length used (b).
min
The dimensions shown could differ from the customer conditions and must potentially be changed by the customer.
NOTICE!
Use grease to mount the VLT
similar.
Use a key in the same material and quality as the hollow shaft.
2.6 Torque Restraint
Shaft-mounted geared motors require a suitable torque restraint to resist the reaction torque. Torque arm with mounting
sets are available as an option (see 6.7.1 Torque Arm Set). It is always important to ensure that the torque arm does not
create excessive constraining forces due to the driven shaft running untrue, for example. Excessive backlash can result in
excessive shock torques in switching or reversing operations.
®
VLT
OneGearDrive Instruction Manual
Shaft
d+0.2
l
e
Shaft
b
c
d
e
f
max
140
8
4
5
100
140
10
5
5
100
140
12
5
5
100
®
OneGearDrive onto the shaft. For example, CASTROL Obeen Paste NH1, ARAL Noco Fluid or
®
MG75C322 - VLT
is a registered Danfoss trademark
x
edges cut
Dimensions (in [mm])
g
h
i
M10
22
30
1)
M12
28
37
1)
1)
M16
36
45
Disc
n
b
max
b
min
Disc
k
l
m
n
o
3
1.5
38
4
29.8
3
1.5
43
4
34.8
3
2
48
4
39.8
2
2
p
11
13
17
2-3