10.2. Pseudo-input Function

The pseudo-input function for the CC-Link IE Field network base card allows the pseudo input signals
from
RT ToolBox3.
Usable cases and usage methods are explained below.
No.
Network base card (DQ535) status
1
2
3
4
* A pseudo-input is not possible while an error is occurring.
<Usage method>
(1) Start RT ToolBox3.
(2) Click [Online] - [Monitor] - [Signal Monitor] - [General Signals] in the work space tree, and start the
general-purpose signal monitor.
(3) Click the [Pseudo-input] button.
(4) Input the signal number (6000 or higher) in the "Head signal #" field and click the [Set] button.
(5) Select the check box for the signal to be input, and click the [Bit pseudo INPUT] button.
Not mounted
Mounted
Condition
Network cable not connected
Network cable connected, but a
communication error occurring
In normal communication
 indicates usable, and × indicates not usable.
Pseudo-input Function 10-43