7 Connections and Wiring
7.2. Wiring
7.2.1. For the CC-Link IE Field module
An example of connecting the 2F-DQ535 card and Rockwell PLC (MELSEC-Q series, QJ71GF11-T2)
one-on-one with an Ethernet cable is explained below.
(1) Connect the Ethernet straight cable connector to the 2F-DQ535 card on which the CC-Link IE Field
module is mounted.
(2) Connect the other connector to the hub.
(3) Connect the Ethernet straight cable connector to the P1 (for Ethernet) on QJ71GF11-T2.
For the star type, connect the connector to either of P1 or P2.
(4) Connect the other connector to the hub.
MELSEC PLC
master station
7-24 Wiring
Controller
Robot
Controller
Robot
Hub
Ethernet
straight
cable
2F-DQ535-CF card
Ethernet straight
cable
Hub
Ethernet
straight
cable
2F-DQ535-CF card
CC-Link IE Field